Skip to main content

Historic roof windows in listed buildings: permit, models and installation

Kenny Kent BridgewaterFromKenny Kent BridgewaterExpert for resource-efficient and sustainable buildingAs of:

A roof window changes the appearance of a roof more than almost any other component. On a listed building or an old timber frame house, it helps decide whether the house keeps its character. Historic steel roof windows are built after the old originals from northern Europe: narrow black frames, small formats, glazing bars and round arches. But they have insulating glass and a thermally decoupled construction. In this article I show you when you need a heritage permit for a roof window, what monument conservation pays attention to, which models there are and how installation works.

Historic roof windows at a glance

Characteristic data of the steel roof windows in the shop, according to the manufacturer's data sheet

FeatureValue
FrameSteel, galvanised (ZnAl 85/15), powder-coated RAL 9005
GlazingInsulating glass 4-15-33.2, laminated safety glass inside, Ug 1,0 W/m²K
Uw value1,25 to 1,60 W/m²K depending on model
SealDouble-lip EPDM profile with snow lip
Corrosion protectionClass C4-h
Sound insulationRw 35 dB
Minimum roof pitch26°
ManufactureHandmade in a Belgian metal forge

What a historic roof window is

A historic roof window is a small steel roof window whose shape and dimensions are based on the windows formerly installed in barns, farmhouses and town houses in northern Europe. The width is based on the old roof pantiles. Most historic windows were designed for four pantiles, some for six. Today's formats have developed from these widths.

From the outside you see a thin, black steel frame lying flat in the roof covering. The glazing bars divide the glass area as in the old originals, vertically, as a cross or as an X. Some models finish at the top with a round arch, others straight.

The difference from an old cast-iron window lies in the construction. The windows have insulating glass with a Ug value of 1,0 W/m²K, a thermally decoupled frame with an insulated inner box and a double EPDM seal. This lets you convert an attic into living space without changing the appearance of the roof.

When you need a permit

You do not need a building permit for a roof window in a residential building in Lower Saxony. The annex to § 60 of the Lower Saxony Building Code exempts openings for windows in completed residential buildings and the replacement of windows in existing openings from permit procedures. Other regulations, for example a development plan or a local design statute, still apply.

For a listed building it is different. Under § 10 of the Lower Saxony Monument Protection Act, anyone who alters, repairs or restores a cultural monument needs a permit from the monument protection authority. A new roof window alters the monument; replacing an old window with a new one also falls under this. The lower monument protection authority at the district or town is responsible.

Even if your house itself is not a monument, a permit may be required. If it is in the vicinity of a listed building and the window affects its appearance, § 10 also applies. This applies, for example, to houses on a listed farmstead or in a protected village centre.

For the application you need photos of the roof, a roof view or site plan showing the position of the windows, the window data sheet with dimensions and elevation, and a short description of the work. You can download the data sheet for each model on the product page. I advise you to talk to the authority before applying. Many questions about size and position can be clarified that way.

What heritage conservation looks for

Historic steel roof windows in a roof with red clay tiles

Monument conservation checks whether the roof is preserved as a calm, closed surface. Large window bands, shiny frames and windows that protrude above the covering disturb this image. Small, dark windows that lie within the covering, on the other hand, hardly stand out.

The questions concern the number and size of the windows in relation to the roof area, their position relative to each other and to the windows in the facade, the frame colour and the division of the glass area. The black powder coating in RAL 9005, the slim profiles and the glazing bars of the historic roof windows correspond to what was customary on old roofs.

For a timber frame house or a barn with clay pantiles, I recommend the smaller formats. A DRKK 40/60 with cross glazing bar or a DRK 40/60 with round arch brings light into the attic and remains discreet in the roof surface. If you need more light, it is better to place several small windows in a row than one large one.

The models at a glance

I carry thirteen models in the shop. The smallest are the DRM 26/40 with round arch without glazing bars and the windows in the format 40/60 and 44/60. The DRKR 44/60 is the only model with a turn-and-tilt fitting.

In the medium size 60/70 there are four variants that differ in shape and glazing bar pattern: DRP 60/70 with round arch, DRPR 60/70 straight at the top, DRPK 60/70 with cross glazing bar and DRPM 60/70 with central glazing bar. The DRF 50/90 is narrow and tall.

For large attic rooms there is the DRX 77/118 with X glazing bar and the three-part DRG 100/110, in which only the middle window opens. The DRV 90/120 is designed as an emergency exit with gas springs; the DRV 90/120 RWA additionally has a chain motor with a control unit for smoke and heat extraction.

The larger the window, the better the Uw value, because the frame proportion decreases. It ranges from 1,60 W/m²K for the DRM 26/40 to 1,25 W/m²K for the DRV 90/120. All models require a roof pitch of at least 26°.

Build-up and technique

The windows consist of a 2 mm thick mounting plate and a 3 mm thick steel flap. The steel is coated with zinc and aluminium in a ratio of 85 to 15 and powder-coated black. Corrosion protection reaches class C4-h. The hinges are made of stainless steel.

The glass is an insulating glass with the build-up 4-15-33.2. Toughened safety glass is on the outside, laminated safety glass on the inside, with a black warm-edge spacer between them. The Ug value is 1,0 W/m²K, light transmission 76 %.

The inner box is insulated and thermally separated from the outer frame. This keeps the inside warm, and less condensation forms on the frame and reveal than with an old, uninsulated steel window. The double-lip EPDM seal with an additional snow lip keeps out rain and driven snow.

Emergency exit and smoke vent

Every dwelling needs two escape routes on every storey with habitable rooms. The second can lead via a window that the fire brigade can reach. In Lower Saxony, the implementing regulation of the NBauO sets the dimensions: the clear opening of the window must be at least 0,90 m wide and 1,20 m high, and the sill may be at most 1,20 m high. If the window is in the roof slope above the eaves line, its lower edge, measured horizontally, may be at most 1 m from the eaves line.

For this purpose, the DRV 90/120 with emergency exit built in. Two gas springs hold the sash open. Clarify with your planner or roofer before ordering whether the position on the roof and the clear dimension fit in the individual case.

The DRV 90/120 RWA is a smoke and heat exhaust ventilator according to the product standard EN 12101-2. A chain motor opens the window via a control unit with switch. Such a window is installed at the top of a stairwell when fire protection requires an opening for smoke extraction. The geometric opening is 1,05 m².

Installation in old buildings and timber-framed houses

Historic roof window with vertical glazing bars between old timber beams in the converted attic

The window is installed in the roof surface from the outside and connected to the roofing. This work belongs in the hands of a roofer. The DRG 100/110 and the DRV 90/120 RWA weigh over 50 kg and are delivered by freight carrier.

Inside you can do preparatory work yourself and save costs. Clear the area, cover the floor, remove the old reveal and take out the old insulation and vapour barrier. With an old window you take off the sash; the hinges are usually just screwed on.

After installation, connect the insulation and the airtight layer cleanly to the window frame. In a roof with clay or wood fibre, the reveal can be finished with clay plaster on a wood fibre board or with Clay boards make. You fill joints between frame and rafters with Stuffing hemp .

For a timber frame house, check the condition of the rafters and battens at the installation point beforehand. A new window is a good opportunity to replace rotten timber.

Historic roof windows in the shop, data according to the manufacturer
ModelSize (W × H)DivisionSpecial featureUw value
DRM 26/4026 × 40 cmwithoutRound arch1,60 W/m²K
DRK 40/6040 × 60 cmverticalRound arch1,50 W/m²K
DRKK 40/6040 × 60 cmCross1,50 W/m²K
DRKR 44/6044 × 60 cmverticalstraight at the top, tilt and turn1,50 W/m²K
DRP 60/7060 × 70 cmverticalRound arch1,40 W/m²K
DRPR 60/7060 × 70 cmverticalstraight at the top1,40 W/m²K
DRPK 60/7060 × 70 cmCross1,40 W/m²K
DRPM 60/7060 × 70 cmGlazing bar in the centre1,40 W/m²K
DRF 50/9050 × 90 cmvertical1,40 W/m²K
DRX 77/11877 × 118 cmX glazing bar1,30 W/m²K
DRG 100/110100 × 110 cmthree-partstraight at the top, centre opens1,30 W/m²K
DRV 90/12090 × 120 cmverticalRound arch, emergency exit1,25 W/m²K
DRV 90/120 RWA90 × 120 cmverticalRound arch, smoke vent1,25 W/m²K

Historic roof windows in northern Germany

In northern Germany, hall houses, barns and timber frame houses with large, closed roof areas shape the townscape. Many of these roofs are being converted today. I advise you on choosing the windows and on the documents for the application. Lehm-Revival is located at Danziger Str. 59, 28832 Achim. I deliver the windows by parcel or haulier.

Are you planning roof windows on a listed building or timber frame house? In 30 minutes on the phone we go through model, size and documents for the application.

Book telephone advice

Frequently asked questions about historic roof windows

Do I need a permit for a roof window on a listed building?

Yes. In Lower Saxony, under § 10 NDSchG, anyone who alters a cultural monument needs a permit from the monument protection authority. A new roof window and the replacement of an old window are included. You submit the application to the lower monument protection authority of your district or town.

May I install a roof window without a building permit if my house is not a listed building?

In Lower Saxony, window openings in completed residential buildings are exempt from permit procedures. A development plan or design statute can nevertheless set requirements. If your house is in the vicinity of a listed building, a heritage permit may also be required.

Which historic roof window is suitable as an emergency exit?

The DRV 90/120 with emergency exit. It has gas springs that hold the sash open. For the second escape route, the clear opening of the window must be at least 0,90 × 1,20 m and close enough to the eaves. Clarify this with your planner before ordering.

From which roof pitch can I install the windows?

All historic roof windows in the shop require a roof pitch of at least 26°.

Does condensation form on steel roof windows?

The windows have insulating glass with a Ug value of 1,0 W/m²K and an insulated, thermally separated inner box. This keeps the inside warmer than with an old, uninsulated steel window. A clean connection of the insulation and the airtight layer to the frame is important.

Created by Kenny Kent Bridgewater, certified expert for resource-efficient and sustainable building with clay building materials. Clay building, timber construction and life cycle assessment in northern Germany. Advice from the author →

To take away: the free clay building diary with drying log.

Download free of charge