Schönthaler hemp block: CO₂-negative masonry block made of hemp & natural lime
CO₂-negative hemp block, the sustainable masonry block for interior insulation, timber stud construction an…




SKU: LR-LL-IH-HS36-PAL
Gross price incl. 19 % VAT
The IsoHemp hemp block 36 cm from the Plus range has tongue and groove and is made for solid external walls in skeleton construction. In Germany it has the general building authority approval Z-17.25-1331 as infill masonry with IsoHemp adhesive mortar.
Volume discount for full pallets
Deducted automatically in the basket.
Set the first course on a damp-proof membrane (projecting on both sides, joints overlapping by at least 20 cm) in a bed of masonry mortar 1–2 cm thick and align it; without rising damp, directly in adhesive mortar, on timber or OSB with construction adhesive foam. Outside, start at least 20 cm above ground level or set on a rot-proof insulating block or the IsoHemp angle profile. Lay further courses only with IsoHemp thin-bed adhesive mortar in two strips of 9 cm each on the bed face (TRU09 notched trowel); the tongue-and-groove perpend joints stay open, only corners are bonded vertically. Half-block bond, offset at least one block thickness. Rasp and brush the top of the previous course, remove excess adhesive with the trowel, never rub joints with water (otherwise they show in the plaster). Cut with an alligator, band or hand saw, no reciprocating saw. Work between +5 °C and +30 °C, free of frost and rain.
Protect pallets from rain, but do not wrap them in plastic film or tarpaulin: the blocks must breathe. Outdoors with a protective hood up to 6 months, opened pallet and uncovered masonry up to 3 months, masonry under a finished roof up to 1 year with at most one winter. Keep the hood and cover masonry and opened pallets with it in the evening.
Permissible wall height with fixing at top and bottom: 8,50 m (application notes).
Hemp shives (grain 2–20 mm) with a mineral binder of air lime and hydraulic lime.
Limit deviations length and thickness ±4 mm, height −1,5/+1,0 mm; flatness and plane parallelity of the bed faces at most 2 mm; moisture expansion at most 3,2 mm/m; thermal expansion 15,3 x 10⁻⁶ 1/K.
IsoHemp product sheet hemp block 36 (as of 10/2026)
IsoHemp technical data sheet hemp block (as of 04.09.2026)
IsoHemp application notes (as of 08/2026)
Technical approval ATG 3169 hemp blocks (UBAtc, valid until 05.02.2031)
General building authority approval Z-17.25-1331 (DIBt)
IsoHemp brochure Syst'HEMP Pro
Environmental product declaration B-EPD 025-0078-002 hemp block 36 cm (French, valid until 06.10.2030)
IsoHemp brochure Syst'HEMP Wood (timber construction)
| Pallet size | 120 x 100 x 114 cm |
| Dry bulk density | 270 kg/m³ |
| Fresh bulk density | 320 kg/m³ |
| Material requirement | 8,3 blocks per m² of wall, adhesive mortar approx. 6,8 kg/m² with an approx. 3 mm thin-bed joint. |
| Pieces per pallet | 25 |
| m² per pallet | 3 m² |
| Compressive strength | 0,2 N/mm² |
| sd value | 1 m |
| Technical quality | Fire resistance 240 min for masonry plastered on one side, plaster on the fire side (manufacturer's data from fire test, ; in Germany according to abZ Z-17.25-1331 fire-retardant F4-B up to 30 m wall height). Weighted sound reduction index Rw 44 (-1;-6) dB, simulated value for plastered masonry; according to abZ Z-17.25-1331 Rw 43 dB plastered on one or both sides (mass per unit area with plaster at least 150 kg/m²). Sound absorption coefficient 0,85. Shear bond strength of the masonry with IsoHemp adhesive mortar fvk0 0,04 N/mm², plaster adhesion 0,09 N/mm² (failure in the block), according to ATG 3169. |
| Thermal conductivity λD | 0,068 W/mK |
| Building physics | Thermal resistance dry 5,37 m²K/W, at 50 % relative humidity 5,07 m²K/W (NBN EN 1745). Phase shift 23,6 h (ISO 13786). Specific heat capacity 1.600 J/kgK. |
| Fire behaviour (EN 13501) | B-s1, d0 (without plaster) |
| Thermal conductivity λ | 0,071 W/mK |
| Water vapour diffusion resistance μ | 2,8 |
| Fastening | Objects according to approval ATG 3169: light loads with wood screws from 6 mm diameter and 60 mm screw-in depth, at most 5 kg per fixing point; heavier loads with wood screws 8 mm and 95 mm depth or the IsoHemp special anchor, at most 10 kg; even heavier loads with chemical anchoring, 90 mm deep, at most 50 kg per point. The manufacturer's application notes give higher values (8 x 80 mm up to 18 kg, 10 x 80 mm up to 37 kg); the limits of the approval are authoritative. The masonry itself is always fixed to the load-bearing structure: as a facing leaf with at least 5 fixings per m² outside and 3 per m² inside, at the wall head with the EQLI-PLA connecting bracket. |
| Working temperature max. (°C) | 30 °C |
| Working temperature min. (°C) | 5 °C |
| Application (further note) | Cut the last row so that at most 2 cm remains to the ceiling, and close the joint with mortar, soft insulation or mounting foam. Span openings with the IsoHemp lintel (bearing at least 20 cm per side, 2 cm from 30 m opening) or with IsoHemp brackets every 60 cm. Cut chases with a wall chaser, fill cavities with crushed block offcuts and ProKalk. |
| Approval number | Technical approval ATG 3169 (UBAtc, Belgium), valid 06.02.2026 to 05.02.2031, for hemp blocks 7,5 to 36 cm with IsoHemp adhesive mortar; general building authority approval and general construction technique permit Z-17.25-1331 (DIBt) for infill masonry, valid until 20.01.2031 |
| CO₂ balance | Biogenic carbon in the product 61,97 kg CO₂ per m² of wall made of hemp block 36 cm (environmental product declaration B-EPD 025-0078-002 according to EN 15804+A2, externally verified, valid until 06.10.2030). |
| Eco certificate | Environmental product declaration B-EPD 025-0078-002 (Belgium), valid until 06.10.2030 |
| Capillary activity | Capillary water absorption 8,1 g/m²s, initial water absorption 2,9 kg/m²·min (bedding side) |
| Sorption value | Volume-related moisture content ψ23-50 0,012 m³/m³ |
| Distinction | Non-load-bearing: the hemp block carries itself and no further loads. Approval ATG 3169 assesses it neither as a substrate for external thermal insulation composite systems with plaster or brick slips nor as a substrate for tiles, and makes no statement on sound insulation. Do not leave it unclad outside; protect it from driving rain and splash water with plaster or cladding. In Germany, the general building authority approval Z-17.25-1331 applies only to infill masonry of this block laid in thin bed with IsoHemp adhesive mortar and without mortared perpend joints, for building heights up to 18 m and in wind zones I to III inland; the approval notice must be available on site. Up to 4 m wall height the masonry is fire-retardant (F30-B); adjoining components must be at least fire-retardant. |
| Format | 600 x 200 mm (module size L x H, block length 596 mm), thickness 360 mm |
| Surface treatment | Outside, only mineral lime plaster without cement in two layers, together 15–25 mm, or ventilated cladding. Inside, PCS, lime or clay plaster with reinforcing mesh at material transitions; in showers and bathrooms, tiles only on a waterproof plaster. |