With the IsoHemp hemp block 15 cm you fill timber framing and timber studs where the panel cross-section fits, and build stronger interior insulation. The block is self-supporting, the structure carries the loads; it closes the surface with hemp and lime.

ManufacturerIsoHemp
Weight546 kg
Purchase price536,17 €
WhatsApp|Email|

Volume discount for full pallets

2 %2 pallets3 %3 to 4 pallets4 %from 5 pallets

Deducted automatically in the basket.

Shipping costsfrom 139,90 € (freight)
Delivery time4-8 working days
PaymentPayPal, credit card, prepayment, invoice for companies

Product details

Application

Set the first course on a damp-proof membrane (projecting on both sides, joints overlapping by at least 20 cm) in a bed of masonry mortar 1–2 cm thick and align it; without rising damp, directly in adhesive mortar, on timber or OSB with construction adhesive foam. Outside, start at least 20 cm above ground level or set on a rot-proof insulating block or the IsoHemp angle profile. Lay further courses only with IsoHemp thin-bed adhesive mortar in bed and perpend joints of approx. 3 mm; apply the mortar with the TRU15 notched trowel. Half-block bond, offset at least one block thickness. Rasp and brush the top of the previous course, remove excess adhesive with the trowel, never rub joints with water (otherwise they show in the plaster). Cut with an alligator, band or hand saw, no reciprocating saw. Work between +5 °C and +30 °C, free of frost and rain.

Delivery and storage

Protect pallets from rain, but do not wrap them in plastic film or tarpaulin: the blocks must breathe. Outdoors with a protective hood up to 6 months, opened pallet and uncovered masonry up to 3 months, masonry under a finished roof up to 1 year with at most one winter. Keep the hood and cover masonry and opened pallets with it in the evening.

Other

Permissible wall height with fixing at top and bottom: 4,00 m (application notes).

Sustainable quality

Hemp shives (grain 2–20 mm) with a mineral binder of air lime and hydraulic lime.

Dimensions and design

Limit deviations length and thickness ±4 mm, height −1,5/+1,0 mm; flatness and plane parallelity of the bed faces at most 2 mm; moisture expansion at most 3,2 mm/m; thermal expansion 15,3 x 10⁻⁶ 1/K.

Technical data

Dimensions

Pallet size120 x 100 x 119 cm

Weights

Dry bulk density270 kg/m³
Fresh bulk density320 kg/m³

Areas & coverage

Material requirement5,5 blocks per m² of wall, adhesive mortar approx. 5,6 kg/m² with an approx. 3 mm thin-bed joint.

Boards & piece logic

Pieces per pallet42

Pallets & packaging

m² per pallet7,56 m²

Building material properties

Compressive strength0,2 N/mm²
sd value0,42 m
Technical qualityFire resistance 60 min for masonry plastered on one side, plaster on the fire side (manufacturer's data from fire test, ; no German fire resistance class). Weighted sound reduction index Rw 38 (0;-3) dB, simulated value for plastered masonry. Sound absorption coefficient 0,85. Shear bond strength of the masonry with IsoHemp adhesive mortar fvk0 0,04 N/mm², plaster adhesion 0,09 N/mm² (failure in the block), according to ATG 3169.
Thermal conductivity λD0,068 W/mK

Building physics values

Building physicsThermal resistance dry 2,24 m²K/W, at 50 % relative humidity 2,11 m²K/W (NBN EN 1745). Phase shift 9,8 h (ISO 13786). Specific heat capacity 1.600 J/kgK.
Fire behaviour (EN 13501)B-s1, d0 (without plaster)
Thermal conductivity λ0,071 W/mK
Water vapour diffusion resistance μ2,8

Installation & assembly

FasteningObjects according to approval ATG 3169: light loads with wood screws from 6 mm diameter and 60 mm screw-in depth, at most 5 kg per fixing point; heavier loads with wood screws 8 mm and 95 mm depth or the IsoHemp special anchor, at most 10 kg; even heavier loads with chemical anchoring, 90 mm deep, at most 50 kg per point. The manufacturer's application notes give higher values (8 x 80 mm up to 18 kg, 10 x 80 mm up to 37 kg); the limits of the approval are authoritative. The masonry itself is always fixed to the load-bearing structure: as a facing leaf with at least 5 fixings per m² outside and 3 per m² inside, at the wall head with the EQLI-PLA connecting bracket.

Application

Working temperature max. (°C)30 °C
Working temperature min. (°C)5 °C
Application (further note)Cut the last row so that at most 2 cm remains to the ceiling, and close the joint with mortar, soft insulation or mounting foam. Span openings with the IsoHemp lintel (bearing at least 20 cm per side, 2 cm from 30 m opening) or with IsoHemp brackets every 60 cm. Cut chases with a wall chaser, fill cavities with crushed block offcuts and ProKalk.

Fire protection & standards

Approval numberTechnical approval ATG 3169 (UBAtc, Belgium), valid 06.02.2026 to 05.02.2031, for hemp blocks 7,5 to 36 cm with IsoHemp adhesive mortar

Moisture, density & heat

Capillary activityCapillary water absorption 8,1 g/m²s, initial water absorption 2,9 kg/m²·min (bedding side)
Sorption valueVolume-related moisture content ψ23-50 0,012 m³/m³

Other technical details

DistinctionNon-load-bearing: the hemp block carries itself and no further loads. Approval ATG 3169 assesses it neither as a substrate for external thermal insulation composite systems with plaster or brick slips nor as a substrate for tiles and makes no statement on sound insulation. Do not leave it uncovered outside; protect it from driving rain and splash water with plaster or cladding. There is no German building authority approval for this thickness; abZ Z-17.25-1331 only applies to the 36 cm block.
Format600 x 300 mm (module size L x H, block length 596 mm), thickness 150 mm
Surface treatmentOutside, only mineral lime plaster without cement in two layers, together 15–25 mm, or ventilated cladding. Inside, PCS, lime or clay plaster with reinforcing mesh at material transitions; in showers and bathrooms, tiles only on a waterproof plaster.

To go with it: my free clay building diary with drying log.