ClayTec HFA dünn D=8mm
Thin wood fibre finishing board as a plaster base on wood, the easiest way to a secur…


SKU: 09015-EINZEL| EAN: 4042356997609
Gross price incl. 19 % VAT(approx. 33,14 €/m²)
Heavy clay board LEMIX D=16 mm, excellent sound insulation and thermal mass with the smallest possible wall thickness.
Volume discount for full pallets
Deducted automatically in the basket.
plus 1 × 25,00 € refundable EUR pallet deposit
625 × 1.250 mm · 16 mm thick · 0,78 m²/board · approx. 18,0 kg/board
Cut with a jigsaw or circular saw. Plaster the clay side, not the jute side. Boards offset by 90° to the substructure, bottom row with a small gap to the floor, butted as tightly as possible without gaps. Offset joints by one stud spacing; cross joints and continuing the edges of wall openings with joints are not permitted. Junctions with solid components with joints. As cladding on level mineral walls, bond in a thin coat with clay adhesive and reinforcing mortar and additionally anchor at the edge and in the field every 300 mm (penetration depth ≥ 30 mm). Do not carry out joint and coating work below about +10 °C room temperature. Close the perimeter joint with ClayTec clay joint filler. Remove dust; fill gaps from 1 mm in full depth with clay adhesive and reinforcing mortar, close holes, even out changes in thickness broadly, pre-wet lightly if necessary. Thin coat: 3 mm clay adhesive and reinforcing mortar with glass mesh 112, then YOSIMA felted, clay filler and surface filler (Q3) or clay top plaster fine 06. Thick coats are not sensible on clay boards; wall heating: spatter coat up to max. 8 mm.
Do not dry wet-applied clay coatings quickly, e.g. with construction dryers or sudden heating, otherwise deformation and cracks can occur. All fillings and levelling must dry before the reinforcement layer. 40–70 % relative humidity is favourable for storage and installation, and max. 70 % after installation too.
Store lying flat on pallets in the warehouse, dry. Storage is possible indefinitely. Protect from wet during transport and storage on site. Carry upright with two people; the ClayTec carrying aid 182/400 is recommended. On site, store lying flat and level on dry pallets or timbers. Relative humidity during storage and after installation max. 70 %.
Approx. 23 kg/m². Allow a reserve of approx. 15 % for fixings.
Values for the selected variant: Single board
| Board length | 1250 mm |
| Board width | 625 mm |
| Board type | LEMIX (heavy clay board) |
| m² per pallet | 46,8 m² |
| Boards per pallet | 60 pcs |
| Offcut recommendation | 10 % |
| Area per board | 0,78 m² |
| Packaging notes | shrink-wrapped |
| Fire protection class | A2 (DIN 4102-1) |
| Technical quality | Surface hardness ≤ 15 mm, flexural tensile strength ≥ 0,8 N/mm², surface tensile strength ≥ 0,1 N/mm². Dimensional accuracy class MHK II: length and width ± 4 mm, thickness +1 mm / -3 mm, flatness -1 mm. |
| Fire behaviour (EN 13501) | A2-s1 d0 |
| Specific heat capacity cp | 1,1 kJ/kgK |
| Bulk density | 1.450 kg/m³ |
| Thermal conductivity λ | 0,625 W/mK |
| Heat storage | 25,5 kJ/m²K |
| Water vapour diffusion resistance μ | 5/10 |
| Sorption class (water vapour) | III |
| Fastening | Timber: LEMIX clay board screws 5 x 60 mm or TN quick-build screws with coarse thread, spacing ≤ 200 mm, 4 fixing points per crossing of board and substructure (wall 12 or 20, ceiling 20 screws/board), flush with the board; penetration depth at least 25 mm. Staples 45 mm, spacing 80–100 mm, penetration depth 30 mm. Metal: C-profile TN quick-build screws, UA-profile TB quick-build screw with countersunk washer. |
| Substructure grid | Walls axis spacing 312,5 mm (= 1.250 mm/4); ceilings and roof slopes max. 312,5 mm. With parallel installation, spacing of the substructure max. 312,5 mm. |
| Material requirement | 1,28 boards/m² |
| Bulk density class | 1.6 |
| Sustainable quality (features) | Clay, loam, wood fibres, starch, jute · pure clay mass · water vapour sorption WS III · reaction to fire A2-s1 d0 |
| Special notes | Timber substructure: solid wood (softwood) according to DIN EN 14081-1 or glulam according to DIN EN 14080, at least C24, grading class S10, wood moisture max. 18 %. Metal: sheet steel profiles according to DIN 18182-1 / DIN EN 14195. Back perimeter substructure members with ClayTec drywall tape. No fixing directly to load-bearing components such as rafters or ceiling joists. |