Skip to main content
ClayTec HFA maxi D=25mm from Lehm-Revival
ClayTec HFA maxi D=25mm, view 2, from Lehm-Revival

ClayTec HFA maxi D=25mm

SKU: 09226-EINZEL| EAN: 4042356092267

39,78 €
fast delivery
3-5 days

Gross price incl. 19 % VAT(approx. 16,97 €/m²)

Oversized wood fibre finishing board for professionals, large areas in fewer work steps, butt joint.

ManufacturerClayTec
Weight14,6 kg
Purchase price39,78 €
WhatsApp|Email|

Volume discount for full pallets

2 %2 pallets3 %3 to 4 pallets4 %from 5 pallets

Deducted automatically in the basket.

Shipping costsfrom 89,90 € (freight)
Delivery time3-5 days

plus 1 × 25,00 € refundable EUR pallet deposit

PaymentPayPal, credit card, prepayment, invoice for companies

Product details

Scope of delivery

1.875 × 1.250 mm · 25 mm thick · 2,34 m² per board · approx. 14,6 kg/board

Application

Plaster the printed, light, sanded side. Can be installed upright or horizontally, offset by 90° to the substructure, bottom row with a gap to the floor, butted as tightly as possible. Timber: ClayTec clay board screws 5 x 50 mm, spacing max. 200 mm, or staples 45 mm, spacing max. 65 mm. Offset joints by one stud spacing; cross joints are not permitted. Wall grid centre spacing 625 mm, ceiling grid 417 mm or 469 mm. Cut pieces under 3 cm wide can separate in the glued layers. Do not carry out joint and coating work below about +10 °C room temperature. Close the perimeter joint with ClayTec clay joint filler, remove dust, do not pre-wet HFA. Fill gaps from 1 mm in full depth with fine clay mortar. Thin coat: 3 mm clay adhesive and reinforcing mortar with glass mesh 112, then YOSIMA rubbed. Thick coat: primer DIE ROTE, clay base plaster with straw, clay plaster Mineral 20 or SanReMo, max. 8 mm per layer (ceiling 5 mm), total max. 15 mm (ceiling 10 mm), at least two layers.

Drying and standing times

Do not dry wet-applied clay coatings quickly, e.g. with construction dryers or sudden heating, otherwise deformation and cracks can occur. All fillings and levelling must dry before the reinforcement layer. 40–70 % relative humidity is favourable for storage and installation, and max. 70 % after installation too. With thick clay plaster layers on HFA, ensure rapid drying, supported with suitable equipment if necessary.

Delivery and storage

Store lying flat on pallets in the warehouse, dry. Storage is possible indefinitely. Protect from wet during transport and storage on site. On site, store lying flat and level on dry pallets or timbers. Protect edges from damage. Relative humidity during storage and after installation max. 70 %.

Coverage and consumption

Thickness 25 mm, approx. 6,25 kg/m². Allow a reserve of approx. 15 % for fixings.

Certificates & test marks

Technical data

Values for the selected variant: Single board

Dimensions

Board length1875 mm
Board width1250 mm

Weights

Bulk densityapprox. 250

Boards & piece logic

m² per pallet105,3 m²
Boards per pallet45 pcs
Offcut recommendationapprox. 10 %
Area per board2,34 m²
Material requirementapprox. 0,4 boards/m²

Pallets & packaging

Packaging notesshrink-wrapped

Building material properties

Fire protection classE
Specific heat capacity2,1 kJ/kgK
Thermal conductivity λ0,05
Water vapour diffusion resistance μ5

Building physics values

Compressive strength≥ 150 kPa
Sorption class (water vapour)III (board coated with 3 mm clay adhesive and reinforcing mortar and 2 mm YOSIMA clay design plaster)

Thermal & moisture values

Heat storage13,1 kJ/m²K (Cp 2,1 kJ/kgK)

Installation & assembly

Wall substructure gridAxis spacing 625 mm (1.875/3 or 1.250/2)

Application

Area of applicationWood fibre finishing board (HFA) for cladding timber and metal stud constructions indoors. For interior walls and linings DIN 4103-1, installation area 1 or 2, for ceiling and roof surfaces.

Fire protection & standards

DIN standardsDIN 4103-1, DIN EN 14081-1, DIN EN 14080, DIN EN 338
EN standardsDIN EN 13501-1

Moisture, density & heat

Water vapour μ value5

Other technical details

Sustainable quality (features)Wood fibres, white glue · breathable · large format matched to the 62,5 cm drywall grid · low-emission · fire class E
Special notesTimber substructure: solid wood (softwood) according to DIN EN 14081-1 or glulam according to DIN EN 14080, at least C24, grading class S10, wood moisture max. 18 %. Metal: sheet steel profiles according to DIN 18182-1 / DIN EN 14195. Back perimeter substructure members with ClayTec drywall tape. No fixing directly to load-bearing components such as rafters or ceiling joists.

To go with it: my free clay building diary with drying log.

Download free of charge
39,78 €

Further expert knowledge

Installation, variants and areas of use of clay boards are explained in the article Clay boards in interior finishing: drywall construction with clay according to DIN 18948.

How wood fibre boards complement interior finishing is described in the article Clay in interior finishing: a healthy indoor climate with natural building materials.